D-SUB Connectors for Field Bus Systems
-with Screw Terminal Connection
SUBCON-PLUS
co
s.
nt
ne
po
The plugs are especially suited for use in RS 485 bus
systems in which an incoming and an outgoing bus
cable must be connected in one D-SUB connector.
SUBCON-PLUS can be connected quickly and conveniently under field conditions without soldering or
crimping tools. The plug-in contacts are connected to
numbered screw terminal blocks and it goes without
saying that there is a separate termination block for
each of the two cable entries. This produces a
systematic overview of the wiring and simplifies
every system start-up.
The connector is available as socket and pin version
suitable for nearly all bus systems. The terminating
resistors are connected at the start and end of the bus
to the free second termination block or, in some
versions, using a slide-type switch (version for
PROFIBUS).
m
1. Short Description
The connectors, designed for the smallest dimensions, can be used for transmission speeds up to 12
Mbit/s. The shielded connector housing guarantees
high immunity to interference.
The direction from which the cables are introduced
can be decided on-site. The connection block can
be installed either in the upper or lower shell of the
housing. It is thus possible to introduce the cable at
an angle of 0° ... 90° from the right or the left.
16
60
10
44
on
l
in
ec
om
Fig. 1
36
Fig. 2
Headquarters: © Phoenix Contact GmbH & Co. • Flachsmarktstraße 8-28 • 32825 Blomberg • Germany
Phone +49-(0) 52 35-3-00 • Fax +49-(0) 52 35-3-4 1200 • http://www.phoenixcontact.com
SUBCON-PLUS D-SUB Connectors for Field Bus Systems -with Screw Terminal Connection
2. Technical Data
SUBCON-PLUS
with two cable entries
Fig. 3
2.1. Description
Order No. Pin assignment
e.g. for use in bus system:
Pcs.
Pkt.
pin
27 61 82 6
1, 2, 3, 5, 6, 8
PROFIBUS
MODBUS
MODBUS-PLUS
BITBUS
ARCNET
MULTI / MININET, B&R
SYSTEM 2003, B&R
P-NET
1
SUBCON-PLUS M2
pin
27 61 83 9
2, 3, 4, 5, 7, 9
CAN
SUCONET K1, K2, Klöckner Moeller
S-BUS, SAIA
J-BUS, MERLIN GERIN
1
SUBCON-PLUS-PROFIB
pin
27 44 34 8
3, 8,
resistor can be connected
via slide-type switch
PROFIBUS to 12 Mbit/s
1
SUBCON-PLUS F1
socket
27 44 26 7
1, 2, 3, 5, 6, 8
MODBUS
MODBUS-PLUS
BITBUS
ARCNET
MULTI / MININET, B&R
SYSTEM 2003, B&R
P-NET
1
SUBCON-PLUS F2
socket
27 99 49 0
2, 3, 4, 5, 7, 9
CAN
SUCONET K1, K2, Klöckner Moeller
S-BUS, SAIA
J-BUS, MERLIN GERIN
1
SUBCON-PLUS F3
socket
27 61 87 1
2, 3, 6, 7, 8, 9
CAN OPEN
FIP
1
SUBCON-PLUS F4
socket
27 44 08 9
2, 3, 4, 5, 6, 7
CAN, KEBA
1
SUBCON-PLUS F5
socket
27 44 10 2
MODBUS, CEGELEC
1
12 02 39 9
blade: 0.4 x 2.5 x 75 mm, length: 150 mm
1
27 99 69 4
short version (without knurl)
20
2.3. General Data
Plug connection
Max. voltage
Current carrying capacity
Plug cycles
Cable diameter (max./min.)
Fixing screws/torque
9-pos. D-SUB pin strip
60 V AC/DC
1A
> 50
10 mm/6 mm
4-40 UNC/0.4 Nm
Screw terminal blocks:
Connection cross section (solid/stranded/AWG)
Torque
Temperature range
Housing material
0.14-1.5 mm2/0.14-1.0 mm2/AWG 26-14
0.4 Nm
-20 °C to +75 °C
ABS-V0, metal-plated
PHOENIX CONTACT page 2 of 2
http://www.phoenixcontact.com
Pcs.
Pkt.
Order No.
TNR: 5087785-00
ne
1, 1, 2, 3, 6, 7
01.02.99
on
l
Screwdriver
SZN/K
Optional fixing screw,
SUBCON-SHORTSCREW
po
om
in
ec
2.2. Accessories
nt
s.
co
m
SUBCON-PLUS M1
PHOENIX CONTACT
Type 9-pos.